Why a generator trips under load
A generator has a rated output, the amount of power it can supply continuously, and a higher surge capacity that it can supply for a few moments. Every generator also has a built-in breaker or protective device on its outlets that opens when current is too high. When you plug in more than the generator can supply, the breaker trips, the engine bogs down or the voltage sags.
There are other reasons, too. A short circuit in a cord or appliance can trip the generator breaker instantly. A ground fault, where current leaks to ground through damaged insulation or moisture, can trip a ground-fault protected outlet. A poor connection at a plug or an inlet can heat up and cause voltage drop that looks like an overload.
Finally, the generator itself can be at fault. A dirty carburetor, a clogged filter, stale fuel or a weak engine can keep the unit from delivering its rated power. If the generator trips under a light load that should be well within its rating, the generator may need service, and the problem may not be on the wiring side at all.

Running watts and starting watts
Appliances use power in two ways. The running load is what they draw once they are operating. Motors, such as those in refrigerators, pumps and air conditioners, need extra current for a moment when they start, often several times the running amount. That brief surge is the starting load.
A generator must handle the running loads of everything on at once, plus the largest starting surge. If you start a refrigerator, a pump and a fan at the same moment, the combined surge can exceed the generator's capacity even if the running totals are fine. Staggering the startup, so that each motor reaches speed before the next starts, is a simple way to avoid trips.
Appliance labels show watts or amps, and some show a separate starting figure. If only amps and volts are shown, multiplying them gives an approximate wattage. If you are unsure, an electrician can help you estimate loads. Our page on extended outage food and medical power offers ideas for choosing what to power first.
Building a load list
This list is not complicated, but doing it before the outage rather than during one reduces trips and stress. Keep a copy with the generator. If you are not sure about a number, a technician can read the nameplate and walk you through it.
- Write down the essentials you actually need: refrigerator, a few lights, a fan, phone chargers and any medical equipment.
- Find the running power of each on the label or the manual.
- Add up the running totals and compare to the generator's continuous rating, leaving a margin.
- Identify the motor loads and their starting surge, and make sure the largest surge fits in the generator's surge rating on top of what is already running.
- Decide on a start order: the biggest motor first, then smaller loads one at a time.
- Leave nonessential heavy loads, such as electric ranges, dryers and central air conditioning, off unless the generator and the connection are designed for them.
- Recheck the total when anything is added, including a fan or a charger.
Overloading the generator is not harmless
A trip is the generator protecting itself. Resetting and trying again without changing the load simply repeats the trip. If a generator does not have a working breaker or if the breaker has been bypassed, the engine and alternator can overheat. A generator that runs overloaded for long periods can damage its windings, overheat its wiring and shorten its life.
Voltage sag is a more subtle issue. A generator that is straining may deliver reduced voltage, which can harm motors, refrigerators and electronics. Lights that dim, motors that hum and appliances that behave oddly when a load is added are signs of sag. Switch off some loads before the generator stalls.
Heat is another factor. Portable generators in South Florida's summer heat run hotter than in cool conditions, and exhaust heat can scorch nearby materials. Place the generator outdoors with plenty of clearance, never under a covered porch, in a garage or close to windows, and never enclose it to protect it from rain, since that can cause overheating and carbon monoxide to enter the house.
Inlet boxes and what can go wrong with them
Many homeowners connect a portable generator to the house through a generator inlet, a weatherproof receptacle on the outside wall wired to a transfer switch or an interlocked panel. The inlet and the cord that links it to the generator carry large current, and every connection along that path must be tight, clean, dry and rated for the load.
Common problems include corroded or pitted pins and sockets, loose internal terminals in the inlet box, water that has entered a box without a proper cover, a bent or burned pin, and a mismatch between the inlet's rating and the generator's output. A high-resistance connection heats up under load, and the heat can melt plastic, discolor the box and cause the generator or the panel to trip.
If you notice a warm or discolored inlet, a burning smell near the plug, or a cord that is hot to the touch, shut down the generator and disconnect the load if it is safe to do so. Do not keep running the generator through a hot connection. Our page on a plug melted into an outlet describes how similar heat damage appears at ordinary receptacles.
Cord sets: gauge, length and condition
The cord between the generator and the inlet, or between the generator and an appliance, matters as much as the generator. A cord that is too thin for the current or too long for the load causes voltage drop and heat. A cord that is cut, crushed or worn can short or leak current to ground, which trips protective devices and creates shock hazards.
Use only cords rated for outdoor use and for the current they will carry, and check the rating on the cord jacket. Keep cords as short as practical, and do not coil a cord that is carrying a heavy load, since coils trap heat. Do not run cords through doorways in a way that pinches them, and do not cover them with rugs, which hides damage and traps heat.
A cord that has become hot, soft or discolored should be taken out of service. Our page on a cord or extension that is hot explains why. Replacing a damaged cord is far less costly than the consequences of continuing to use it.
Ground fault trips and wet conditions
Many generators have ground-fault protection on some outlets, and many extension cords and power strips used outdoors do too. A ground fault happens when current takes an unintended path to ground, for example through water or damaged insulation. The protective device trips to prevent shock.
Rain and humidity during a storm increase the chance. Moisture in a plug, a cord end or an appliance can cause leakage. Place cord connections off the ground and under cover that does not enclose the generator, and keep them dry. Do not stand in water when connecting or disconnecting equipment.
If a ground-fault outlet trips repeatedly, do not bypass it. Our page on a GFCI that will not reset explains how it works and what its behavior can mean. A trip is information: something is leaking current, and it needs attention before the generator is used with that equipment again.
What an electrician checks on arrival
If the problem involves a house inlet, a transfer switch or an interlock, the electrician checks the whole path. They measure voltage at the generator, at the inlet and at the panel under a controlled load, and they look for voltage drop along the path. They inspect the inlet box, the cord ends and the breakers for heat damage.
They also review the connected load against the generator's rating, and they may help you build a priority list of circuits to power. If the generator is oversized for the cord or the inlet, or if the inlet is undersized for the generator, they say so and recommend corrections. If the generator itself seems at fault, they suggest a generator service technician, since the engine and alternator are a different trade.
Our page on a transfer switch that does not move power covers the case where the generator runs but the house stays dark. Our page on whether to repair or replace after a failure helps if you are weighing the cost of fixing an older inlet box or cord.
Realistic situations
A homeowner in Miramar powers the refrigerator, a few lights and a window air conditioner from a portable generator. When the air conditioner compressor starts, the generator breaker trips. The technician explains that the compressor's starting surge exceeds the margin. The owner staggers the startup and runs a fan instead of the air conditioner during the outage.
In a Pompano Beach home, the generator trips whenever a particular cord is connected. The cord has a small nick that lets current leak when it is wet. Replacing the cord fixes the problem. Another household in Plantation notices that the inlet box on the wall is warm and smells of hot plastic after an hour of running. The inlet's pins are pitted from years of exposure to salt air, and replacing the inlet and cord set removes the heating.
A family in Sunrise tries to run the central air conditioner and an electric range from a small portable unit. The generator stalls repeatedly. Instead of buying a larger generator on the spot, they ask an electrician to help them plan a priority list for the next storm. Each of these cases involved a different cause: surge, leakage, a poor connection, and a load beyond capacity.
Fuel, maintenance and a generator that runs poorly
Not every trip is an electrical fault. A generator that surges, hunts for speed or stalls when loaded may be suffering from stale fuel, a clogged carburetor, a dirty air filter or old spark plugs. Gasoline left in a tank over a humid summer can degrade and gum up the fuel system, and a unit that has sat unused for a year often needs service before it can deliver its rated output.
Before hurricane season, run the generator under a modest load for a while, listen for smooth operation and check that its outlets deliver normal voltage. Follow the maker's instructions for fuel storage and oil changes. If the engine runs rough, if the exhaust smells unusual or if the unit trips under a load that should be well within its rating, the generator needs a service technician rather than a wiring repair.
Keep records of what you ran and for how long. A short test with a load list in hand shows what the generator can really carry, and it reveals weak cords and inlet connections while there is still time to fix them. It is far easier to replace a corroded cord in July than in the middle of a storm warning.
Safety rules that apply whenever a generator runs
Our page on backfeeding the house with a generator explains why a shortcut connection is dangerous, and our page on generator safety after a hurricane collects more precautions.
- Run the generator outdoors only, well away from windows, doors, vents and enclosed spaces, to avoid carbon monoxide entering the home
- Keep a working carbon monoxide alarm indoors and check it before the season
- Let the generator cool before refueling, and store fuel safely away from the unit and from ignition sources
- Do not connect the generator to the house through an outlet or a double-ended cord
- Keep the generator dry, without enclosing it in a way that traps heat or exhaust
- Do not operate it with wet hands or while standing in water
- Keep children and pets away from the generator, the cords and the exhaust
Getting help and planning for the next outage
If your generator trips, overheats or behaves oddly, shut it down, let it cool and call. Describe the generator's make and rating, what you were running, what tripped, whether the inlet or cords felt hot and whether you smelled anything. Say whether it happened in rain or on dry ground.
Quotes are given only by phone. A service call charge applies and is explained before dispatch. If the problem involves an inlet, transfer switch or panel work, a complicated job needs an on-site visit before a quote can be given. The dispatcher cannot promise arrival windows during a widespread outage, but can explain how the process works.
If you smell fuel, see smoke or fire, or suspect carbon monoxide, move outdoors and call 911 first. Otherwise, call the number on this page, and the dispatcher will explain the next step. A short conversation before the next hurricane season can turn a stressful outage into a managed one.
Questions people ask
Why does my generator trip when I plug in the air conditioner?
An air conditioner compressor draws a large surge when it starts, often several times its running load. If the generator's surge capacity or margin is too small, the breaker trips or the engine stalls. Starting it before other loads, using a smaller cooling option such as a fan, or choosing a generator sized for it can help. A technician can estimate your loads.
What is the difference between running watts and starting watts?
Running watts are what an appliance draws once it is operating. Starting watts are the extra surge motor-driven appliances need for a moment when they start. A generator must supply the running total of everything on plus the largest starting surge. Staggering startups, so motors start one at a time, helps keep within the generator's capacity.
My inlet box or cord feels hot. Is that normal?
No. A hot or discolored inlet, plug or cord indicates high resistance or overload, and heat can melt plastic and start a fire. Shut down the generator, let everything cool and do not keep using that connection. A technician can inspect and replace the inlet, cord or pins if they are worn or corroded.
Can I just reset the generator breaker and keep going?
Resetting once after reducing the load is reasonable. Resetting repeatedly without changing anything repeats the trip and can stress the generator. Find out why it tripped: too much load, a short in a cord, a ground fault or a poor connection. If it trips under a light load, the generator or the wiring may need a technician.
Is it safe to run the generator in the garage with the door open?
No. Carbon monoxide can enter the home from a garage even with the door open, and it is invisible and odorless. Run the generator outdoors, well away from windows, doors and vents, and keep a working carbon monoxide alarm indoors. If the alarm sounds or anyone feels dizzy or ill, move outside and call 911.
How do I get a price for checking my inlet and cord set?
Quotes are given only by phone. A service call charge applies and is explained before dispatch. A simple inlet or cord replacement can be described over the phone, while a complicated job involving the panel or transfer switch needs an on-site visit before a quote can be given. Have the generator's rating and the inlet's label details ready if you can read them safely.
About "Generator Trips When You Load It": call and give us the details, and we will explain what is safe to do while you wait and what the visit would cover. Jobs that cannot be quoted blind need a look on site.
Related pages
- Backfeed Danger: Plugging a generator into a wall outlet can send power back onto the utility lines. Learn why backfeeding is dangerous and what proper isolation involves.
- Transfer Switch Fault: The generator is running but the house stays dark. Learn why a transfer switch may not move power, what is safe to check and what a technician will test.
- Hot Cord: A hot extension cord or power strip is overloaded or damaged. Learn how to unplug it safely, why permanent cord use fails, and when to call an electrician.
- Generator Safety: Portable generator safety after a hurricane: placement, carbon monoxide, refueling, cords and backfeed, with when to call 911 and when to call an electrician.
- Inlet and Transfer: Plain-language guide to generator inlets, interlocks and transfer switches, and why they are safer than backfeed cords. For homeowners planning ahead.
- Small Fire: Small flames at an outlet, cord or appliance still mean get out and call 911. Learn why water is wrong, when an extinguisher is an option and what follows.