Safety first: shock, water and burning smells
A GFCI or AFCI that trips is usually working as intended, but the situations around it can be dangerous. If anyone has been shocked, call 911 and see our page on a person shocked at home. If a device is smoking, hot, or smells burnt, or if you see sparks, treat it as a fire risk, switch off power at the panel if you can reach it safely, and call 911 if there is smoke or flame. Do not stay near a device that is arcing.
If water is involved, such as a leak onto an outlet, a flooded garage, or a wet outdoor receptacle, keep away from it and keep others away. Do not reset a ground fault device that is wet. A tripped device in a wet location is a warning that current is leaking, and resetting it may energize wet equipment. Wait until the area is dry and a qualified electrician has looked at it.
If the situation is calmer, such as a bathroom outlet that trips on rainy days or a bedroom breaker that trips whenever a certain lamp is on, it is still worth treating seriously. These devices are the last line of defense against shock and fire. A device that trips repeatedly is telling you something real, and a device that has failed silently may be offering no protection at all.

What GFCI and AFCI devices actually protect against
A ground fault circuit interrupter compares the current flowing out on the hot wire with the current returning on the neutral. If they differ by a very small amount, it means current is leaking through another path, perhaps through a person, through water or through a damaged appliance. The device opens the circuit in a fraction of a second, which can prevent a fatal shock. GFCI protection is used in bathrooms, kitchens, garages, laundry areas, outdoors, and around pools and spas.
An arc fault circuit interrupter looks for the electrical signature of a dangerous arc, a spark that jumps across a damaged wire, a loose connection or a pinched cord. Arcs can reach very high temperatures and ignite wood framing and insulation without drawing enough current to trip an ordinary breaker. AFCI protection is used on bedroom and living area circuits and is increasingly required throughout the home in new work.
The two protect against different things. A GFCI protects people from shock. An AFCI protects structures from fire. Many modern breakers combine both functions and are called dual function devices. They can be installed in the panel as breakers or, in the case of GFCI, as outlets. Each type has a test button that you should press periodically to confirm that it trips as designed.
Why they trip: nuisance or real fault
People often call these trips nuisance trips, but most have a cause. A ground fault device may trip because moisture is getting into an outlet or a fixture, because a damaged appliance cord is leaking, because a pool pump or a garage freezer has a leaky motor, or because a long run of wire has some leakage in damp conditions. A sprinkler hitting an outdoor outlet can do the same. These are real leakage events, even if the amount is small.
An arc fault device may trip because of a damaged cord, a loose connection in an outlet, a nail or screw through a cable, a pinched wire behind a wall, or because some appliances such as vacuum cleaners and power tools produce harmless arcs that the device mistakes for dangerous ones. Compatibility between older devices and certain loads is also a known issue. A technician needs to distinguish a real arc from a false alarm.
Both device types can also fail with age. Devices have internal electronics that can wear out, especially after surges, and a failed device may trip randomly, refuse to reset, or stop protecting without any sign. A test button that does nothing is a warning. Treat a device that behaves strangely as unreliable until it is tested. Do not assume that a quiet device is a safe one.
What not to do
Do not bypass or defeat a GFCI or AFCI. Replacing a ground fault outlet with a standard outlet to stop trips, swapping a combination breaker for a plain one, taping a reset button, or wiring around a device removes the protection that is meant to keep you safe. A defeated GFCI in a kitchen or bathroom can turn a minor fault into a fatal shock. A defeated AFCI can let an arc smolder in a wall for hours.
Do not keep resetting a device that trips immediately. Each reset into a fault can stress the device and the wiring. Do not use a long extension cord from another circuit to avoid the trip, since you are only moving the problem. Do not plug a refrigerator or a freezer into a ground fault outlet that you suspect is failing without a plan for protecting the food, since a trip can spoil it unnoticed.
Do not replace the device yourself unless you are properly trained. A GFCI outlet has line and load terminals, and miswiring them can leave the protection inoperative while the outlet appears to work. Breakers sit in panels with live parts. Our page on a GFCI that will not reset and our page on an arc fault breaker that keeps tripping describe the symptoms in more detail.
What you can safely observe and note
You can collect a lot of helpful information without touching a device. Note which device trips: a GFCI outlet, a GFCI breaker, an AFCI breaker or a dual function breaker. Note what else goes dead when it trips, since a GFCI outlet may protect other outlets downstream. Note when it trips: immediately, after some time, when it rains, when a particular appliance is used, or at a particular time of day.
Press the test button on a GFCI outlet once, and make sure it trips and then resets. If it does not trip, or will not reset, tell the technician. Look for signs of moisture around outdoor outlets, in the garage and under sinks. Look at cords and appliances connected to the circuit, such as space heaters, fans, tools, or older equipment with frayed cords. Unplug everything on the circuit and see whether the device then resets and stays on, then add items back one at a time.
That last step is worth doing carefully, and only if the device stays on when everything is unplugged. If it trips with nothing plugged in, stop and call, because the fault is in the wiring. If it holds when empty and trips when you plug in a specific item, you have found a likely culprit, and you should stop using that item. Tell the technician what you found. This test often reveals a failing appliance in a matter of minutes.
- Which device trips: GFCI outlet, GFCI breaker, AFCI breaker or dual function
- What area or outlets lose power when it trips
- Whether it trips with nothing plugged in, or only with one item
- Whether it trips only in rain, humidity or after watering the lawn
- Whether the test button works and the device resets
How a technician traces the fault behind repeated trips
The technician starts with the device and the circuit. They test the device itself, since a worn-out unit can misbehave. They then isolate the circuit: disconnecting loads, checking each outlet, switch and fixture on the circuit for signs of moisture, damage, loose connections and misconnections. They may use an insulation resistance tester to measure leakage on the wiring with the circuit disconnected, which can reveal damaged insulation that is not visible.
For ground fault problems, they look for a neutral-to-ground connection in the wrong place, shared neutrals between circuits, a damaged cable, water in boxes and conduits, and leaking appliances. Shared neutrals are a common hidden cause: if two circuits share a neutral, a ground fault device on one of them will see current returning on the wrong conductor and trip. This arrangement is common in older homes and in some multi-wire circuits.
For arc fault problems, they look for loose connections, damaged cords and cables, nails or screws that have touched a cable, and wires that have been pinched in a box. They check for neutral problems that cause AFCI trips. They may check compatibility with the loads and replace a device with a newer version if appropriate. Tracing can take time, and may need access to walls, attics and crawl spaces, which is why some jobs need more than one visit.
Repair options: replace the device, fix the wiring, or both
Sometimes the repair is simply a new device. A GFCI outlet that no longer trips or resets is replaced. An AFCI breaker that has aged out is replaced with a current one of the right type for the panel. The technician installs the new device, tests it, and confirms the protection is working. Replacement devices must be of the right type and listed for the panel.
Other times the device is fine and the wiring needs repair. A damaged cable is repaired or replaced. A shared neutral is separated. A wet box is dried, sealed or replaced. An outdoor outlet is replaced with a weather-resistant one with an in-use cover. A leaking appliance is retired or repaired by the appropriate trade. Our page on urgent ground fault tracing describes the process for ground faults specifically.
In many homes the solution is a mix, for example replacing a failed breaker and also correcting a shared neutral. The technician should explain what they found and why they are recommending each step. If the repair requires opening walls or running new cable, that is a larger job and is discussed before proceeding. Some work needs a permit, and the technician will explain what applies in your city.
Home types and local conditions
South Florida's humidity, heavy rain and sprinkler systems create plenty of moisture exposure, and ground fault devices on garage, lanai and exterior circuits trip often during the wet season. Older homes, including many in Hollywood, Pompano Beach and parts of North Miami, may have ungrounded outlets, shared neutrals and older wiring that react badly to newer protection devices. Newer homes may have several protective devices in series that interact.
Condominiums and apartments present their own issues. A ground fault outlet in a bathroom may protect outlets in a different room, or a breaker in a unit panel may be linked with other units in ways that are not obvious. Rental homes often see outlets modified over time by different people. Garages with freezers and refrigerators suffer when a ground fault outlet trips unnoticed.
After storms and floods, devices may be affected by water and surge. A device that survives a storm may fail later. If your home was affected by water, see our page on flooded outlets after water intrusion, and our guide on what GFCI and AFCI protect against for background.
Preparing for the call and the visit
When you call, explain which device trips, where it is, what loses power, when it trips and what you have tried. Say whether anything was plugged in, whether it rains, and whether you have noticed warm outlets or odd smells. Say whether the trips began after a change, such as new appliances, a storm or renovation work. The dispatcher will ask about safety and direct you to 911 if anything is dangerous.
Quotes are given only by phone. Replacing a single device can often be described on the call, but tracing a repeating fault through the wiring usually needs an on-site visit before a firm figure can be given. A service call charge applies and is explained on the phone before anyone is dispatched. The dispatcher cannot promise an arrival time.
Before the visit, leave the device alone after one reset that fails, unplug items from the affected circuit, keep pets and children away, and make a note of what loses power. Protect food in a freezer if the trip affects it. When you are ready to have a qualified electrician trace the fault and restore working protection, call and describe what is happening.
- If anyone was shocked or you see smoke, sparks or a burning smell, call 911 first.
- Press reset once, and if it trips again, leave it off.
- Unplug everything on the circuit and see whether it holds, then stop if it does not.
- Note when it trips, what else loses power and what was plugged in.
- Call and describe the device, the pattern and what you tried.
Questions people ask
Why does my GFCI trip when it rains?
Rain suggests moisture entering an outlet, a fixture, a box or a conduit, creating a small leakage path that the device detects. Outdoor and garage circuits are the usual locations. Keep the circuit off until the entry point is found, since the device is warning you about a real leak. A technician can locate and seal it, or replace weather-damaged parts.
Is an arc fault trip just a nuisance?
Sometimes it is a compatibility issue with a certain appliance, but often it signals a real problem such as a loose connection, damaged cord or pinched cable. Treat repeated trips as real until a technician has checked. Unplugging devices one at a time can show whether a particular item is involved, and the results are useful to share.
Can I swap a GFCI for a regular outlet to stop the trips?
No. That removes protection against shock in places where it matters most, such as kitchens, bathrooms, garages and outdoors. A tripping device is reporting leakage that needs to be found. A qualified electrician traces the cause and restores proper protection, so the circuit works safely and the device stays in place.
My GFCI will not reset at all. What does that mean?
It may have failed from age or a surge, or there may be a fault on the circuit that keeps it tripping. Check whether it trips with everything unplugged. If it will not reset in either case, leave it off and call. A technician can test the device and the wiring to see which is at fault.
Why does one GFCI outlet turn off other outlets?
A GFCI outlet can protect other outlets downstream of it on the same circuit through its load terminals, so when it trips, they lose power too. The outlets may be in different rooms, which makes the cause hard to find. Look for a tripped GFCI in bathrooms, garages and outdoors, and mention it to the technician.
How do I find out the price before booking?
Quotes are given only by phone. Replacing a device can often be described on the call, but tracing a recurring fault in the wiring needs an on-site visit before a firm figure can be given. A service call charge applies and is explained on the phone before anyone is dispatched.
About "Urgent GFCI and AFCI Repair": call and give us the details, and we will explain what is safe to do while you wait and what the visit would cover. Jobs that cannot be quoted blind need a look on site.
Related pages
- GFCI Won't Reset: A GFCI that will not reset means a fault or a failed device. Learn what safe checks you can do, what to avoid, and how to describe the problem by phone.
- AFCI Tripping: An arc-fault breaker that keeps tripping may be a nuisance trip or true arcing. Learn how to tell the difference and what a dispatcher will ask you about it.
- GFCI and AFCI Explained: A plain explanation of ground-fault and arc-fault protection, where each is used, what each catches, and the limits that still call for caution.
- Ground Fault Tracing: How a technician isolates a ground fault with testing rather than guesswork, what trips a breaker or GFCI, and what you can safely do while you wait.
- Outlet Repair: A dead, warm or heat-damaged outlet needs attention. Learn what is safe to do, how a technician repairs a receptacle, traces the cause and how to prepare.
- Meter Base Replacement: What to do when a meter base is burned, cracked or pulled loose, who owns which part, and how the disconnect and reconnect sequence works.