Service Mast Bent or Pulling Off the House

The service mast is the pipe rising above the roofline that carries the utility wires into your home. When a storm, a falling limb or a heavy sagging line bends or pulls it, the conductors can tear, short or touch the roof. This page covers what to do and how repair is coordinated with the utility.

What the service mast does

On many homes with overhead service, the electric utility's wires run from a pole to the house and attach to a point near the roof. From there the conductors enter a rigid steel pipe, the service mast, which runs down the wall or through the roof to the meter base. At the top is the weatherhead, a curved cap that lets the wires enter while keeping rain out, and the wires loop in a drip loop below it. A guy or support at the top attaches the utility's line to the house.

The mast does two jobs. It carries the customer-owned service conductors safely down to the meter, and it provides the mechanical attachment point and the clearance above the roof that the utility's overhead line needs. It stands up to the pull of the line, the wind and the weather, year after year, and it is built to be strong. Yet it is not unlimited. A heavy branch, a hurricane gust, a sagging line or a poorly supported mast can bend it.

A mast that leans, kinks or pulls away from the wall is carrying a mechanical failure that can quickly become an electrical one. Bending can strain the conductors inside and tear their insulation. It can loosen the weatherhead and let in water. It can pull the meter base from the wall. In the worst case the wires separate, fall, or touch the roof, a gutter or a metal part and energize it.

Emergency Electrician technician repairing and testing a wall outlet in a South Florida home

That is why this page treats a damaged mast as urgent. The first moves are about keeping people away from the house edge and the wires, and contacting the people who can disconnect service.

How masts get bent or pulled loose

Storms are the main cause. In a hurricane or severe thunderstorm, high winds whip the service line, and trees and limbs fall onto the line or the mast. A tree that falls across the drop pulls hard on the mast and can bend it sharply. Even a branch that rests on the line can load it with weight after rain.

Other causes are more gradual. A line that has been stretched or that sags because the pole or the attachment moved puts a steady pull on the mast. Corrosion in a mast that has been exposed for a long time, especially near the coast, weakens the steel. A mast with insufficient bracing, or one mounted on weak roof framing or fascia, can lean over time. Improper earlier repairs, such as a mast extended or spliced without proper support, are also common weak points.

Roof work and nearby construction can contribute too. A roofer who disturbs the mast, a satellite dish or antenna mounted on it, or a ladder striking it can loosen it. Large vehicles or equipment passing under the line can snag it.

However it happened, the effect is a mast that no longer stands as it should, and that may be holding live conductors under strain. Do not judge the danger by how the mast looks alone, because a mast that appears only slightly bent can hide torn insulation inside. Related events are covered in a tree on the service line and storm-damaged meters and masts.

What to look for from the ground

You can assess a lot from a safe distance without going near the roof or the wires. Look at the mast's angle: is it leaning, bent in the middle, or twisted? Look at the roof flashing and the point where it passes through the roof or is attached to the wall: is it pulled up, cracked or showing gaps? Check the weatherhead at the top: is it torn, hanging, or pointing the wrong way?

Look at the wires. Are they sagging more than usual, stretched taut, or lying on the roof, a gutter, a tree or a fence? Are they separated from the house or from each other? Do you see bare conductors, burn marks or melted insulation? A wire that touches the roof or a metal part can energize it, and a wire on the ground is extremely dangerous.

Look at the meter base and the wall below: is the base pulled from the wall, tilted or cracked? Is the conduit or the cable below the mast bent, kinked or disconnected? Inside the house, look at the lights and listen to the electrical system. Flickering, dimming, partial outages or buzzing can mean damage along the service.

Do not climb, lean a ladder against the house near the mast, or use a pole or stick to look. Metal and even dry wood or fiberglass ladders can be dangerous near energized conductors. Use binoculars or your phone's zoom from the yard, and take photos for later.

  • Mast leaning, kinked or twisted.
  • Weatherhead torn, hanging or pointing the wrong way.
  • Wires sagging, taut, touching the roof, gutter, tree or fence.
  • Roof flashing lifted, cracked or gapped around the mast.
  • Meter base pulled from the wall or tilted.
  • Flickering, dimming or partial outages inside the house.

What to do right now

If any wire is down, sparking, touching the ground or a fence, or if anything is burning, stay far away and call 911. Treat every downed or hanging wire as live, and never approach, touch or move it. Keep others, including children and pets, well back. The page on a downed wire in the yard explains the danger zone and what to tell the dispatcher.

If the wires are still attached but the mast is bent or pulling, call the electric utility's emergency line and report a damaged service mast. The utility can disconnect service at its side, which is the step that makes the situation safe to work on. Tell them the address, what you see and whether any wire touches the roof or the ground.

Switch off the main breaker only if it is safe and easy: the panel is dry, you are not near the damaged parts, and you are not rushing under a wire. This reduces the load but does not make the service safe, because the wires up to the meter and the main stay energized. It is a secondary step, not a replacement for calling the utility.

Keep away from the mast, the roof edge and the wires. Do not park or stand under the line. Do not try to push the mast upright, cut a tree off it, or tie it to something. Do not touch a metal gutter, downspout or railing near the damaged wires if you suspect they touch the house. If you are unsure, step back and wait for crews.

  1. Downed, sparking or burning wires: stay away, call 911.
  2. Call the utility emergency line to report the damaged mast.
  3. Keep everyone and every vehicle clear of the line and roof edge.
  4. Do not touch, push, cut or climb near the mast or wires.
  5. Switch off the main only if it is clearly safe, as a secondary step.
  6. Photograph from a distance and call an electrician.

Who owns which part

Responsibility is split, and the usual split is described here in general terms because it varies among utilities and among installations. The utility generally owns its line up to the point of attachment on the house and, in many cases, the wire that connects to the customer's conductors. The customer typically owns the mast, the weatherhead, the meter base, the service conductors inside the mast and everything from there down to the panel. The meter itself belongs to the utility.

In practice this means that when a storm bends the mast, the utility disconnects or de-energizes its side, and the customer needs a contractor to repair or replace the mast and connected equipment. The utility cannot usually repair the customer's mast, and an electrician cannot lawfully connect or disconnect the utility's wires. The two have to work in sequence.

Some utilities have specific requirements for mast height, size, bracing and clearance over the roof and over driveways, and they may check the new installation or require an inspection before they reconnect. Local building departments commonly require a permit for mast repair or replacement. See who fixes what for the general split.

If your home is a condo, townhome or other shared building, the mast and meter may be owned by an association or building owner. Report the damage to management as well, and keep a record of when and to whom you reported it.

The repair sequence in general terms

The steps usually run in this order. First the utility is notified, and it makes its side safe, for example by de-energizing the service drop. Second, the owner calls an electrician, who assesses the mast, weatherhead, meter base, conductors and the roof penetration. Third, a permit is arranged where required. Fourth, the electrician repairs or replaces the damaged parts, restoring proper support, clearance and weatherproofing. Fifth, the work is inspected. Sixth, the utility reconnects service.

Each of these steps can introduce waiting time, especially after a major storm when many homes are affected at once. No honest contractor can promise when the utility will return. What a contractor can do is prepare and carry out the repair promptly, make it ready for inspection, and keep the paperwork organized so that nothing delays reconnection unnecessarily.

A temporary measure is sometimes possible, but it must be done safely and within the rules, and it usually still requires the utility to disconnect first. Do not accept or attempt any improvised support, such as tying the mast with rope or bracing it with lumber while the wires are live. A mast under tension with live conductors is not a place for experiments.

For the related pages on repair and on the utility process, see urgent service mast repair and the power company disconnect and reconnect process.

What the technician will check and replace

Once service is disconnected and the area is safe, the technician inspects the entire entrance. At the top, they examine the weatherhead, the drip loop and how the utility's wires attach. Along the mast, they check for bends, kinks, cracks and corrosion, the brackets and straps that hold it, and the way it passes through the roof or wall. The flashing and the roof boot are checked for leaks.

Inside the mast, they inspect the conductors for stretched or damaged insulation, nicks and heat marks. They examine the meter base and the conduit, and the connection at the main breaker or disconnect. Any water that has run down the mast and into the panel is taken seriously, because it can cause corrosion and shorts that show up later. The page on a torn weatherhead or water entering the mast covers that part.

Typical repairs include replacing a bent mast with a new one of proper size and bracing, replacing the weatherhead and drip loop, replacing damaged conductors, repairing or replacing the meter base, and restoring the roof seal. Sometimes the roof framing or fascia where the mast is attached needs repair, which may involve a roofer or carpenter as well.

The technician will explain what is needed, what permit applies, and what the inspection will check. If the mast or service is also undersized for current loads, they may mention an upgrade as an option, which is a separate decision.

Preparing for the call and the visit

Have the key facts ready when you call. What happened, and when? Was there a storm or a falling tree? Is the mast leaning, bent or torn off the house? Are wires touching anything? Has the utility been called, did they disconnect service, and do you have a reference number or tag? Is the home single-family or part of an association? Are there any roof leaks or water damage?

Take photos from the yard, wide shots that show the roofline, the mast, the wires and the meter. Do not go closer or climb. Note the pole and wire path if you can see it. Keep driveways and yard access clear so that trucks and ladders can reach the house, and keep gates unlocked.

Plan for time without power, especially for medical needs, food storage and cooling. Keep devices charged, use flashlights rather than candles, and do not run a generator indoors or connect one to the house through improvised cords. If you plan to use a generator, see generator safety after a hurricane.

Quotes are given by phone only. Complicated jobs need an on-site visit, and there is a service call charge, explained on the phone before dispatch. If your mast is bent or pulling, keep clear, make sure the utility knows, and call when you are ready to talk through the repair.

Questions people ask

Can I push the mast back upright or brace it myself?

No. A bent mast usually holds live conductors under tension, and pushing, tying or bracing it can tear the wires or energize metal you are touching. The utility must disconnect its side first, and a contractor then repairs or replaces the mast. Stay away from the roof edge, keep others back and call for help.

A tree branch is resting on the service wires. Can I remove it?

No. Do not touch the branch or the wires. A branch can conduct electricity, and removing it can pull the line or the mast. Call the utility to report it, and call 911 if wires are down, sparking or burning. Crews have the equipment and training to remove it safely once the line is dealt with.

Who pays for the mast repair, the utility or me?

In general terms, the utility owns its line and the meter, and the customer owns the mast, weatherhead, meter base and conductors down to the panel, though details vary by utility and installation. The utility can tell you where its responsibility ends. Insurance may help with storm damage, so photograph everything and read your policy or ask your agent.

Do I need a permit to replace a service mast?

Usually yes. Service entrance work is typically permitted and inspected before the utility reconnects service. Rules differ from city to city across Broward County and the cities from Boca Raton to North Miami, so the contractor can explain the general process for your address, and the local building department decides the specifics.

Is it safe to stay in the house with a bent mast?

It depends. If wires are down, sparking, burning, or touching the roof, evacuate to a safe distance and call 911. If the mast is bent but the wires look intact, the risk may be lower, but it can change quickly. Call the utility, avoid touching metal parts near the entrance and follow the instructions you are given.

What does an on-site visit involve, and how is it priced?

A technician inspects the mast, weatherhead, meter base, conductors and connections once the utility has made the service safe, then explains what is needed. Quotes are given only by phone, and complicated jobs need the visit first so the quote reflects the real damage. There is a service call charge, explained on the phone before dispatch. Call to learn more.

Talk to Emergency Electrician

If "Service Mast Bent or Pulling Off the House" matches what is happening, call and describe it plainly: the room, the breaker, any burning smell or tripped circuit. We explain what the repair would involve before a visit is set.

Related pages

  • Torn Weatherhead: A torn or leaking weatherhead lets rain run down the conduit toward the meter and panel. Learn the danger, the order of coordination and what repair involves.
  • Downed Wire: A wire on the ground may be live even if it is silent. Learn how to keep a safe distance, call 911 and the utility, and what never to do near a fallen line.
  • Mast Repair: A bent, torn or storm-damaged service mast or weatherhead is a hazard. Learn who disconnects power, who repairs what, and how permits and inspection work.
  • Tree on Line: A tree pulled down the service line to your house. Learn who handles mast, drop and conduit damage, what to avoid, and how to coordinate the repair.
  • Mast and Meter: Why damaged meter sockets, masts and weatherheads must be repaired by an electrician before the utility reconnects, and how the process usually works.
  • Small Fire: Small flames at an outlet, cord or appliance still mean get out and call 911. Learn why water is wrong, when an extinguisher is an option and what follows.

Need to discuss an electrical concern or planned project?

Request service
Call (954) 481-0910