Half-Power Symptoms: Lost Leg Explained

Some lights and outlets work, but the dryer will not heat, the oven stays cold and the air conditioner will not start. That pattern usually means one of the two hot legs feeding the house has been lost somewhere between the utility and your panel. This page explains why, where the fault can sit and what to do.

How a home gets its power in two halves

Most homes in the United States are supplied with a split-phase service. Two hot conductors come in, along with a neutral. Each hot carries about 120 volts relative to the neutral, and the two hots are opposite in phase, so the voltage between them is about 240 volts. Ordinary lights, outlets and small appliances use one hot and the neutral. Large loads such as ranges, dryers, water heaters and many air conditioners use both hots together.

In the panel, the two hot bus bars alternate down the length of the panel, so adjacent breakers sit on different hots. A two-pole breaker straddles both. Half of the single-pole circuits in your house are therefore powered by one leg and half by the other, and the large 240-volt circuits need both to be alive.

When one leg is lost, that half of the single-pole circuits goes dead, and any appliance that needs both legs stops working or runs poorly. The house may look half-alive, with some rooms lit and others dark, and with a pattern that does not follow floors or areas the way a single tripped breaker might.

Emergency Electrician technician installing a pendant light in a bright coastal home

What a lost leg looks like at home

Not every symptom is a lost leg. A single tripped breaker or a failed appliance can look similar at first. The giveaway is a pattern: several unrelated 240-volt appliances fail together, and about half of the ordinary circuits are dead as well. Even so, only measurement confirms it.

  • The electric dryer tumbles but does not heat, or does not run at all
  • The electric range or oven stays cold while some burners or the clock may still show a light
  • The air conditioner or heat pump will not start, or the indoor fan runs while the outdoor unit does nothing
  • The electric water heater produces no hot water
  • Roughly half of the lights and outlets are dead, in a pattern that does not match one room or one breaker
  • Some lights are dim, flicker or behave oddly
  • A well pump, pool pump or other 240-volt motor will not run, or hums without turning
  • Breakers all look on, yet things do not work

Why the dryer and oven die while some lights work

A 240-volt appliance needs both hots. If one is missing, there is no 240 volts between them, and the heating element or motor has nothing to run on. Some appliances split their loads, with controls and lights using one leg and elements using both, which is why a range might show a clock or an indicator light but not heat.

Lights and outlets on the surviving leg continue to work normally, since they only need that leg and the neutral. The circuits on the dead leg go dark. Because of how breakers alternate in the panel, the dead circuits are scattered rather than grouped, which can make the problem feel random.

A related and more dangerous condition occurs when the neutral is also compromised. In that case, the surviving leg can show unusual voltage and the house can behave erratically. Our page on signs of a loose or open neutral explains how that differs. A technician measures voltage at several points to tell which fault you have.

Where the missing leg can be lost

The leg can be lost at several points. On the utility side, a blown fuse or failed connection at the transformer, a damaged service drop or a failed splice can drop one hot from the supply to your home. Neighbors may or may not be affected, depending on how the transformer is shared.

On the customer side, the usual suspects are the meter socket jaws, the service entrance conductors, the main breaker and the connections at the bus bar. A burned meter jaw, a loose lug or a failed main breaker can open one leg. Inside the panel, a broken or burned bus connection can do the same. See sparking at a meter socket and a burned or seized main breaker for those cases.

The leg can also be lost on a smaller scale. A single two-pole breaker with one failed pole will drop one leg for the circuit it serves, such as a dryer, and leave the rest of the house alone. In that case, only that appliance is affected, and the house otherwise works. Distinguishing a whole-house lost leg from a single-circuit one is among the first things a technician does.

What you can safely check

Without opening the panel, you can make a few observations that help the dispatcher. Walk through the house and note which lights and outlets work and which do not. Check whether neighbors have power, and whether their lights look normal or dim. Look at the main breaker and the two-pole breakers from the outside of the panel door; do not remove the cover.

You can also check whether any breaker is in a tripped or halfway position by looking at the panel with the door open, if the panel door opens without exposing live parts. If one is, that is useful information, but do not repeatedly reset it. Our page on how to read a tripped breaker explains what the positions mean.

Unplug or switch off the affected 240-volt appliances at their controls. This prevents them from trying to start unexpectedly when power is restored and protects motors from running on partial voltage. Do not test the dryer or oven plug with improvised tools, and do not open an appliance to look for the problem.

Why partial power is more than an inconvenience

A motor that tries to run on reduced voltage can overheat. Air conditioner compressors and well pumps are examples: if a compressor attempts to start without proper voltage, it can draw heavy current, overheat its windings and fail. That is why technicians recommend switching off the thermostat when a lost leg is suspected.

Heat is also a concern at the fault. If the cause is a loose or burned connection, current may be flowing through a poor contact, and the damage can spread to the meter socket, the main or the bus bar. A connection that is partly failed can produce warmth, buzzing or a faint burning smell. These are signs to treat the situation as urgent and to leave the panel and meter alone.

Finally, an uneven supply can damage electronics on the live leg if the neutral is also affected. If the house is behaving oddly, with some lights too bright, switch off sensitive equipment. The dispatcher can help you decide whether the main should be turned off at the panel.

Utility side or customer side: how the call is routed

If neighbors on the same transformer are also seeing partial power or odd dimming, the problem is likely on the utility side, and the utility should be told. If your house is the only one affected, the fault is more likely on the customer side or in the service drop to your home.

A technician measures at the meter socket, the main and the panel to decide. Where the fault lies ahead of the meter, the technician will tell you to contact the utility, and they can help describe the problem so the utility sends the right crew. Where the fault is on the customer side, the technician can repair the equipment after the utility disconnects service if needed.

Our page on who fixes what between the utility and an electrician explains the dividing line. Do not wait to report a utility-side fault because you assume someone else has done so; the utility may not know about your service unless you tell them.

What a technician does on site

The technician measures voltage from each hot to neutral and between the hots at the meter, the main and the panel. They also measure at the affected appliance outlets. A missing reading on one hot identifies the lost leg, and moving upstream from point to point tells them where it disappears.

Once the fault is located, the repair depends on the cause. A loose lug is cleaned and tightened. A burned meter jaw may need the meter socket replaced, and a failed main breaker or damaged bus is replaced. Our page on urgent meter base replacement describes how a meter socket repair proceeds.

Work on the supply side requires the utility to disconnect the service, and replacement of service equipment normally involves a permit and an inspection before the utility reconnects. The technician will tell you whether this applies to your address. Afterward, they should recheck voltage on both legs, confirm the 240-volt appliances operate, and look for heat damage elsewhere.

Single appliance versus whole house

It helps to separate two pictures that can look alike. In the first, one appliance, such as the dryer, has stopped working while everything else in the house is normal. That points to the appliance, its cord, its receptacle or its two-pole breaker. In the second, several different 240-volt appliances have failed together and a scattered half of the lights and outlets is also dead. That points to the supply to the whole panel.

A quick way to tell without touching the panel interior is to count what has failed. If the dryer alone is dead but the oven, the water heater and the air conditioner run normally, a single-circuit fault is likely. If two or more large appliances on separate breakers have failed at once, and you see dead outlets in unrelated rooms, think whole house.

Tell the dispatcher which picture fits. A single-circuit problem can often be handled as an outlet or appliance circuit repair, while a whole-house lost leg involves the service equipment and possibly the utility. Our page on urgent appliance circuit repair covers the single-circuit case in more detail.

Older homes, aluminum conductors and aging service equipment

Lost legs show up more often in older service equipment. Meter sockets that have been in place for decades develop pitting and loose jaws, especially where they have been exposed to rain and salt air. The spring tension that holds the meter blades tight can weaken, and a weak grip heats the contact, which weakens it further.

Aluminum service entrance conductors, common in homes built in certain decades, expand and contract with load and temperature. Over years, that movement can loosen lugs. If the lug was never re-torqued, or if it was tightened with the wrong tool, a leg can start to burn at the connection. The resulting damage may be visible as black or melted areas around the terminal.

Panels from certain eras also have bus bar stabs and breaker clips that lose their grip over time. A technician will compare the condition of what they find against the age of the equipment and tell you whether replacement of a part or a larger component is reasonable. They should show you what they found and explain it in plain words before work begins.

In condominiums, the problem can also arise in the building's riser or in a shared meter bank. If a meter bank serves several units and only yours has lost a leg, the fault may be at your meter position. The association may need to be involved, since access to the meter room is typically controlled.

Temporary measures while repairs are arranged

If the repair cannot happen immediately, some temporary measures can make the wait easier without adding risk. Keep refrigerator doors closed, switch to battery lighting in rooms that are dark, and use only the outlets that are working with normal loads. Avoid running extension cords across the house from a live outlet to a dead area, because cords can overheat when stretched to carry more than they should.

Do not move a 240-volt appliance to a 120-volt outlet or use adapters to make it fit. Do not bridge breakers or use tricks you read online to bring a leg back. Do not run a generator through an outlet to feed the panel. Our page on backfeeding the house with a generator explains why that endangers lineworkers and your own home.

If hot water, cooking or cooling is essential, ask the dispatcher about temporary arrangements. Sometimes a technician can restore a single circuit or provide a temporary connection while a permanent repair is scheduled. Our page on urgent temporary power restoration describes how that works in general terms.

Realistic situations

In a Weston two-story home, the owner puts a load of laundry in the dryer, and it tumbles but stays cold. Soon after, the oven fails to heat. Half the downstairs lights are out. The technician finds a main breaker pole that has burned and opened one leg. After the main is replaced, all circuits return.

In a Miramar townhouse, a tenant reports that the air conditioner will not start although the lights work. The air handler fan hums. The technician measures only one leg at the outdoor disconnect and finds a blown fuse in the disconnect. Replacing the fuse is not the end; the technician checks the compressor for damage from running on a single leg and discusses what he found with the owner.

In a Weston house with a pool, the pool pump hums and the oven will not heat. Neighbors on the same street have normal power. A technician finds a loose connection in the meter socket jaws, burned from heat. The socket is replaced after the utility disconnects service. In each case, the first clue was that 240-volt loads failed while some 120-volt loads worked.

Getting help and what to have ready

When you call, describe the pattern: which appliances failed, which rooms have power, whether neighbors are affected and whether you noticed any smell, hum or flicker. Mention whether you have switched off the main or any breakers, and whether anything changed just before the problem, such as a storm or a utility outage and restoration.

Quotes are given only by phone. A service call charge applies and is explained before dispatch. Because a lost leg can be a loose lug or a failed service component, a complicated job may need an on-site visit before a quote can be given. If you are in a condominium or a rental, notify the association or landlord, since part of the equipment may be theirs.

If you see smoke, sparks or smell burning, call 911 first. Otherwise, switch off the large appliances, keep clear of the panel and call the number on this page, and the dispatcher will explain the next steps.

Questions people ask

Why do some lights work but my dryer and oven do not?

Lights and outlets use one hot leg and the neutral, while dryers and ovens need both hot legs for 240 volts. If one leg is lost, circuits on the surviving leg work and the big appliances do not. About half of the ordinary circuits, those fed by the lost leg, are also dead. A technician measures voltage to confirm and locate the break.

Is a lost leg dangerous?

It can be. A loose or burned connection that causes the lost leg can overheat and damage the meter socket, the main or the panel. Motors that try to run on reduced voltage can overheat, and if the neutral is affected, voltage can be abnormal on the surviving leg. Switch off large appliances, keep clear of the panel and call promptly.

Should I reset the breakers to bring it back?

Check the panel only to see if a breaker looks tripped, and do not open the dead front. Resetting once is generally harmless, but repeatedly resetting a breaker that will not stay on can worsen damage. If the main or a two-pole breaker looks burned, hot or stuck, do not force it. Call and let the dispatcher guide you.

Could this be the utility's problem?

Yes. A failed fuse or connection at the transformer or in the service drop can drop one leg, sometimes for several homes. If neighbors also see dim lights or partial power, tell the utility. If only your home is affected, the cause is more likely on your side. A technician measures at the meter and panel to determine where the leg disappears.

Can I keep running the air conditioner?

It is better not to. A compressor that tries to start without proper voltage can draw heavy current and overheat. Switch the thermostat to off until a technician has restored both legs and confirmed the voltage. If it is very hot indoors, open windows safely and use battery fans, and mention it to the dispatcher so any urgency can be considered.

How do I get a price for fixing a lost leg?

Quotes are given only by phone. A service call charge applies and is explained before anyone is dispatched. The repair might be a simple tightening or a larger job at the meter, main or panel, and a complicated job may need an on-site visit before a quote can be given. Have your symptoms, the address and whether neighbors have power ready when you call.

Talk to Emergency Electrician

If "Half-Power Symptoms: Lost Leg Explained" matches what is happening, call and describe it plainly: the room, the breaker, any burning smell or tripped circuit. We explain what the repair would involve before a visit is set.

Related pages

  • Half-House Outage: Half your home lost power while the rest works. Learn why a split outage can mean a lost leg, what you can check safely, and why to call an electrician.
  • Loose Neutral: Lights that get brighter in one room and dimmer in another, buzzing and failing electronics can mean a loose neutral. Learn the signs and why it is urgent.
  • Seized Main: Main breaker burned, stuck or will not switch off or on: why it happens, why the utility may need to pull the meter and what to do in the meantime.
  • AC Disconnect Burn: A melted or scorched AC disconnect box outside your home is an electrical hazard. See what to do now, who handles which part, and what to tell the dispatcher.
  • Troubleshooting Visit: A walkthrough of an urgent electrical troubleshooting visit: arrival, safety isolation, testing, findings explained in writing, and how phone quotes work.
  • Panel Buzzing: Some panel hum is normal, but loud buzzing can signal arcing or a loose connection. Learn to sort the sounds and what to tell the dispatcher about them.

Need to discuss an electrical concern or planned project?

Request service

Related pages

Call (954) 481-0910